batch 8 Quiz gravimetric + chomatographyBest of luck for the quiz 1 / 70Which of the following types of compounds are best analyzed using Gas Chromatography Non-volatile compounds Large proteins Volatile and thermally stable compounds Highly polar, ionic compounds 2 / 70. Which detector is the most sensitive for detecting organic compounds in GC? Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Electron Capture Detector (ECD) UV-Vis Detector 3 / 70In TLC, which type of compound typically moves the farthest up the plate? Polar compounds Non Polar compounds Ionic compounds Amphoteric compounds 4 / 70The ideal precipitate in gravimetric analysis should Be highly soluble Have a large surface area Form colloidal suspensions Have a well-defined chemical composition 5 / 70The purpose of using a "constant weight" in gravimetric analysis is to Ensure complete precipitation Reduce instrumental errors Avoid hygroscopic changes in weight Confirm the sample is fully dried 6 / 70Which of the following is used as a masking agent in gravimetric analysis EDTA Ammonium hydroxide Hydrochloric acid Sulfuric acid 7 / 70The digestion process in gravimetric analysis helps in Increasing the solubility of the precipitate Decreasing the particle size of the precipitate Coagulating the precipitate for better filtration Preventing precipitation from occurring 8 / 70Which of the following is NOT a common requirement for a precipitate in gravimetric analysis? Low solubility High purity Large crystal size High hygroscopicity 9 / 70Hardness of water can be found by which titration acid base titration complexometric titration precipitation titration redox titration 10 / 70Which type of titration is used to determine the amount of vitamin C in a solution? Acid-base titration Redox titration Precipitation titration Complexometric titration 11 / 70Why is Volhard’s method performed in an acidic medium? To prevent hydrolysis of Ag⁺ To ensure complete precipitation of AgCl To keep Fe³⁺ in solution To increase the solubility of the precipitate 12 / 70Which of the following salts can interfere with precipitation titrations? NaCl AgNo3 Pb(NO₃)₂ Na₂SO₄ 13 / 70What is the major limitation of the Mohr method? It cannot be used in acidic solutions It requires a colored indicator It is only applicable to sulfate ions It requires an external indicator 14 / 70Which of the following titration methods uses back titration Volhard method Mohr method Fajans method Argentometric titration 15 / 70What is the primary basis of gravimetric analysis Color change of the analyte Electrical conductivity of the solution Measurement of the mass of the analyte Change in temperature 16 / 70Which of the following is the first step in gravimetric analysis Drying filtration precipitation Titration 17 / 70Why is a selective reagent used in precipitation To ensure rapid reaction To avoid co-precipitation of unwanted species To increase the solubility of the analyte To enhance the color change 18 / 70Which of the following is commonly used for vacuum filtration Sintered glass funnel Buchner funnel Separatory funnel Conical funnel 19 / 70What is the purpose of drying or ignition in gravimetric analysis To dissolve the precipitate To remove moisture and volatile impurities To increase the solubility of the analyte To facilitate filtration 20 / 70Which of the following compounds is used in gravimetric analysis for determining sulfate content BaSO4 AgCl PbSO4 Na2SO4 21 / 70Gravimetric analysis is considered a fundamental method in classical analytical chemistry because of its High accuracy and precision Rapid results Use of expensive equipment Ability to detect trace elements 22 / 70Which of the following is tested in the filtrate to ensure complete precipitation pH of the solution Presence of residual analyte Volume of the solution Color of the filtrate 23 / 70Which of the following is an application of gravimetric analysis? Determination of sulfate as BaSO₄ Identification of organic compounds Spectrophotometric analysis Gas chromatography 24 / 70Which factor is important for forming a filterable precipitate? The precipitate should be fine and colloidal The precipitate should form large particles The precipitate should dissolve in water The precipitate should be completely soluble in acid 25 / 70Which of the following is NOT a step in gravimetric analysis Precipitation filtration titration drying 26 / 70Which of the following is the correct order of gravimetric analysis steps Precipitation → Digestion → Filtration → Washing → Drying → Weighing Filtration → Precipitation → Drying → Washing → Weighing Drying → Precipitation → Filtration → Washing → Digestion Washing → Drying → Precipitation → Filtration → Weighing 27 / 70The purpose of washing the precipitate is to Dissolve the precipitate Remove excess reactants and impurities Convert the precipitate to a gaseous state Increase the weight of the precipitate 28 / 70Supersaturation occurs when The solubility product (Ksp) is lower than the ionic product The solubility product (Ksp) is equal to the ionic product The solubility product (Ksp) is higher than the ionic product No precipitation occurs 29 / 70Which condition promotes large particle growth in precipitation High supersaturation Low supersaturation Rapid addition of precipitant High stirring speed 30 / 70Digestion is the process of Heating the precipitate in contact with the solution to improve particle size Filtering the precipitate under vacuum Dissolving the precipitate for further analysis Removing moisture from the precipitate 31 / 70Peptization occurs when A precipitate dissolves back into solution due to excess washing with pure water The precipitate forms large crystals The precipitate turns into a gas Digestion is carried out for too long 32 / 70Which impurity is most difficult to remove from a precipitate Occlusion inclusion Surface adsorption post-precipitation 33 / 70What is an example of a precipitate prone to surface adsorption AgCl CaCO₃ NaCl ZnO 34 / 70The gravimetric factor (GF) is defined as: The ratio of the mass of analyte to the mass of the precipitate The molar ratio of analyte to precipitate The total weight of precipitate The conversion factor for grams to moles 35 / 70Which of the following properties is important for a precipitate in gravimetric analysis High solubility Volatility Stability under heating Bright color 36 / 70Which of the following is not a requirement for a precipitate in gravimetric analysis Large particle size High solubility Known composition purity 37 / 70In precipitation, the formation of fine particles instead of large filterable ones is called nucleation Co-precipitation Precipitate aging adsorption 38 / 70Which of the following conditions favors the formation of large precipitate particles? Rapid addition of reagent Slow addition of reagent with stirring Using a high concentration of reagent Increasing temperature suddenly 39 / 70The process of allowing a precipitate to stand in solution before filtration is called Drying digestion adsorption elution 40 / 70What type of filter paper is commonly used for gravimetric analysis? Ordinary filter paper Ashless filter paper Chromatography paper coated filter paper 41 / 70Gravimetric analysis is commonly used to determine the concentration of Gases ions in solution Organic compounds radioactive substances 42 / 70In paper chromatography, what is the primary force that helps separate components Gravity Capillary action Centrifugal force Electromagnetic force 43 / 70What is the role of a "developing chamber" in paper chromatography To heat the sample for faster separation To maintain a saturated atmosphere of solvent vapors To provide an electric field for separation To dissolve the sample before it moves 44 / 70Why is a reference sample often used in paper chromatography To verify the purity of the solvent To provide a basis for comparison with unknown samples To clean the paper before use To prevent the solvent from evaporating too quickly 45 / 70What is the primary reason for using a mixture of solvents in the mobile phase To increase the speed of separation To dissolve different components with varying polarities To decrease the Rf values of all compounds To prevent the paper from dissolving 46 / 70In a two-dimensional paper chromatography setup, why is the paper rotated 90° before the second run To improve separation of overlapping spots To increase the Rf values To ensure all compounds move to the same position To dry the paper before re-running the experiment 47 / 70What is the mobile phase in paper chromatography The filter paper sample solvent filter paper 48 / 70Which of the following solvents would likely move a polar compound faster in paper chromatography Water ethanol hexane acetone 49 / 70Which of the following is NOT a common application of paper chromatography Identifying plant pigments Separating amino acids Analyzing hydrocarbons in petroleum Detecting drugs in biological samples 50 / 70What is the formula for calculating the Rf value Distance traveled by solvent / Distance traveled by solute Distance traveled by solute / Distance traveled by solvent Distance traveled by solute × Distance traveled by solvent Distance traveled by solvent – Distance traveled by solute 51 / 70Why is pencil used instead of ink to draw the baseline in paper chromatography? Pencil marks do not dissolve in the solvent Pencil marks are easier to erase Pencil reacts with the solvent Ink improves the separation process 52 / 70What is the purpose of spraying the chromatogram with ninhydrin in amino acid analysis? To visualize colorless amino acids To dissolve the sample completely To increase the Rf values To make the paper more absorbent 53 / 70The separation of compounds in TLC is based on Differences in molecular weight Differences in adsorption affinity Differences in melting point Differences in boiling point 54 / 70What does a higher Rf value indicate in TLC Stronger interaction with the stationary phase Weaker interaction with the stationary phase Higher molecular weight of the compound Increased retention time 55 / 70Which solvent system would be most appropriate for separating nonpolar compounds in TLC? ethanol acetone acetic acid hexane 56 / 70What is the advantage of using TLC over column chromatography? TLC is faster and requires less solvent TLC can handle large sample volumes TLC gives better resolution TLC is more suitable for large-scale purification 57 / 70The stationary phase in Gas Chromatography is typically A solid adsorbent A liquid coated on a solid support A metal surface a gas 58 / 70What type of compounds are best analyzed using Gas Chromatography? Volatile and thermally stable compounds high molecular weight compounds Strongly polar ionic compounds Insoluble solids 59 / 70What is the mobile phase in Gas Chromatography (GC) Liquid solvent Inert gas Solid adsorbent High-pressure liquid 60 / 70If a compound does not move from the baseline in TLC, what could be the reason The compound is highly polar and strongly adsorbed to the stationary phase The solvent is too polar The compound is volatile and evaporated The TLC plate was overheated 61 / 70The separation of components in GC is primarily based on differences in molecular weight solubility boiling point UV absorbance 62 / 70Commonly used detector in GC is FID UV visible Refractive index all 63 / 70What type of detector is best suited for detecting halogenated compounds in GC Thermal conductivity detector (TCD) Electron capture detector (ECD) Flame ionization detector (FID) UV detector 64 / 70The retention time of a compound in GC depends on Column temperature Flow rate of carrier gas Polarity of the stationary phase all 65 / 70. What is the effect of increasing the column temperature in GC Decreases retention time Increases retention time Increases peak broadening Does not affect separation 66 / 70Which of the following gases is commonly used as a carrier gas in GC He CO2 O2 H2 67 / 70Discoverer of chromatography michael tswett Henry Richard walliam watson John crick 68 / 70Locating reagent used for phonols is ninhydrin 10% H2SO4 FeCl3 chromate solution 69 / 70What is the role of a guard column in GC To separate compounds To protect the analytical column from contaminants To increase retention time to cool the sample 70 / 70If peak tailing occurs in a GC chromatogram, what could be the possible reason? Poor injection technique Overloading of the column Contaminated stationary phase all Your score isThe average score is 0% 0% Restart quiz